Chemical anchor capsules for fast, stress-free fixing of studding and rebar into masonry and concrete. Pre-measured resin and hardener in a single glass capsule. No mixing, no mess, no guesswork. Available in M8 to M24.
Size
QTY
Price
QTY
M8
10
£6.90£8.28
M10
10
£6.90£8.28
M10
10
£8.90£10.68
M12
10
£9.90£11.88
M16
10
£10.90£13.08
M20
6
£13.90£16.68
m24
6
£15.90£19.08
A resin chemical anchor capsule is about as close to foolproof chemical anchoring as you are going to get on site. Each capsule contains a pre-measured blend of resin and hardener sealed inside a glass vial. Drill your hole, drop the capsule in, drive the stud or rebar through it with a rotary hammer, and the spinning action breaks the glass and mixes the chemistry. Job done. No cartridge guns, no nozzles to block, no two-part mixing ratios to get wrong at seven in the morning.
These capsules are used wherever you need a high-strength, load-bearing fixing into concrete, brick, stone, or blockwork. The self-contained nature of the system makes them particularly useful when you are working in confined spaces or awkward positions where handling a separate injection gun is impractical. They are also a sensible choice when you only need a handful of fixings and do not want to open a full cartridge.
Where Resin Chemical Anchor Capsules Perform Best
The sweet spot for this type of fixing is structural applications: setting holding-down bolts, anchoring steel framework, fixing rebar into existing concrete for extensions or reinforced pours, and installing threaded rod for mechanical plant supports. The resin fills the annular gap between the hole wall and the stud, creating a bond that distributes load across the full embedment depth rather than relying on mechanical expansion alone. That is why they are preferred in cracked concrete zones and close to edges where expansion anchors would not be appropriate.
Size Range and Selection
These capsules are available from M8 right through to M24, which covers the vast majority of structural fixing requirements. Match the capsule size to the stud diameter and follow the recommended hole size and embedment depth for each diameter. Getting the hole size right is critical — too loose and the capsule does not mix properly, too tight and you will not get it in at all. The hole depth should be at least as deep as the capsule length plus a small tolerance for glass fragments and debris.
Sold in boxes of 6 or 10 depending on size, these are a practical stock item for structural fixers, groundworkers, and steelwork contractors who want a reliable, repeatable chemical anchoring solution without the fuss of a full injection system.
Pro Tip: Always use a rotary hammer in rotary-only mode to drive the stud through the capsule — switching to hammer-only or SDS hammer action will shatter the glass without mixing the resin properly and you will end up with a weak, inconsistent bond.
Resin chemical anchor capsules are used across structural and civil engineering applications wherever a reliable, high-load fixing into concrete or masonry is required. Common uses include setting threaded studding for steel connections, anchoring rebar into existing concrete slabs or walls, installing holding-down bolts for plant and machinery, and fixing safety-critical supports such as barrier posts and lifting points. They are widely used by steelwork erectors, groundworkers, civil contractors, and structural fixers.
Best For
Threaded studding installation in concrete
Rebar anchorage and continuity fixing
Holding-down bolts for structural steel
Plant and machinery base fixings
Safety-critical anchor points
Compatible With
Normal weight concrete
Solid brick and natural stone
Solid blockwork
Threaded rod and studding M8 to M24
Rebar in compatible diameters
Key Features
Pre-measured resin and hardener in one capsule
No cartridge gun or mixing nozzle required
Self-mixing on stud installation
Full annular gap fill for distributed load transfer
Available M8 to M24
Sold in boxes of 6 or 10
Not suitable for: Not suitable for use in hollow masonry, aerated blocks, or profiled sheet materials where the capsule cannot be properly contained. Not recommended for wet or water-filled holes where resin cure will be compromised.
Drill the hole to the correct diameter and depth for the capsule size being used. Clear the hole thoroughly with a blow-out pump and brush to remove all dust and debris — this step genuinely matters, as dust contamination between the resin and the hole wall is the most common cause of anchor failure. Insert the capsule into the clean, dry hole.
Fit the threaded stud or rebar into a rotary hammer chuck with a suitable drive adaptor. Set the hammer to rotary-only mode and drive the stud through the capsule at a steady pace, maintaining continuous rotation. The glass breaks and the resin components mix as the stud advances. Hold the stud in position without moving it until the resin has cured to the manufacturer's specified cure time, which varies with ambient temperature. Do not apply load until full cure is achieved.
Select the correct capsule size to match your stud or rebar diameter
Drill the hole to the specified diameter and embedment depth for that capsule size
Clean the hole thoroughly using a blow-out pump and hole brush, repeating at least twice
Check the hole is dry before inserting the capsule
Drop the capsule into the hole
Fit the threaded stud to a rotary hammer using an appropriate drive adaptor
Set the rotary hammer to rotary-only mode — no hammering
Drive the stud through the capsule with continuous rotation until fully embedded
Hold the stud stationary and do not disturb until the resin has fully cured
Check the manufacturer's cure time for your ambient temperature before applying any load
Can I use these capsules in wet or damp holes?
No. Standing water in the hole will interfere with the resin cure and significantly reduce the bond strength. The hole must be dry before the capsule is inserted. If water ingress is unavoidable, use a chemical anchor system specifically rated for wet or underwater conditions.
Do I need a special tool to install the stud into the capsule?
You need a rotary hammer drill and a suitable drive adaptor to fit the threaded stud into the chuck. The hammer must be set to rotary-only mode. A standard drill will not generate enough torque to break the capsule and mix the resin consistently, and a hammer-only setting will shatter the glass without mixing.
Each capsule contains polyester or vinylester resin combined with a hardener and aggregate filler, encapsulated in a borosilicate glass vial. When the stud is driven through under rotation, the glass fractures and the components combine to form a high-strength thermoset polymer bond within the drilled hole. The cured resin fills the annular gap completely, providing load transfer in both tension and shear without inducing radial stress in the substrate.
Product Type
Chemical Anchor Capsule
Available Sizes
M8, M10, M12, M16, M20, M24
Box Quantity
6 or 10 (size dependent)
Installation Method
Rotary hammer, rotary-only mode
Substrate Compatibility
Concrete, solid brick, solid blockwork, natural stone
Fixing Type
Threaded studding, rebar
Weight
N/A
Size
M10, M12, M16, M20, M8, m24
Box Quantity
10, 6
Product Type
Chemical Anchor Capsule
Reviews
There are no reviews yet.
Be the first to review “Resin Chemical Anchor Capsule”Cancel Reply
Reviews
There are no reviews yet.